How should I define initial vertical and lateral dimensions for volume sources?


When a volume source is chosen, the initial dimensions of the volume source plume must be determined.  The table below from "Screening Procedures for Estimating the Air Quality Impact of Stationary Sources, Revised" (EPA-454/R-92-019, October 1992) provides a summary of the Suggested Procedures for Estimating Initial Lateral Dimension (syo) and Initial Vertical Dimension (szo) for Single Volume Sources. 

Description of Source

Initial Lateral Dimension Initial Vertical Dimension

Surface based source

(he ~ 0)

syo = side length / 4.3 szo = vertical dimension / 2.15

Elevated source (he > 0) on

or adjacent to building

syo = side length / 4.3 szo = building height / 2.15

Elevated source (he > 0) not

on or adjacent to building

syo = side length / 4.3 szo = vertical dimension / 4.3
Last update:
2010-06-02 16:34
Author:
Gareth Davis
Revision:
1.1
Average rating: 2 (1 Vote)